Q&A
-
2015-10-22 What are the advantages of Weavers SF6 Density mic...
Swiss imported pressure sensor, pressure automatic compensation, Swiss imported dew point sensor, sensor automatic calibration, the monitor uses laser spot welding to ensure air tightness, the monitor shell is made of stainless steel, most of the same industry aluminum alloy material;
Learn More -
2015-10-08 How to understand Weavers' Extended Warranty Servi...
Extended warranty service - As the name suggests is a kind of service to extend warranty. At present, more and more manufacturers have launched extended warranty services, especially high-end products related to the people's livelihood. For users, buying extended warranty services at a lower cost can bring more peace of mind and convenience in addition to product protection.
Learn More -
2015-09-23 Effects of sulfur hexafluoride on atmospheric envi...
In the last hundred years, the earth's climate is undergoing a significant change with global warming as the main feature. This global warming is caused by both natural climate fluctuations and the greenhouse effect, which is enhanced by human activities. Reducing greenhouse gas emissions and mitigating climate change is the main goal of the United Nations Convention on Climate Change and the Kyoto Protocol, but China is facing more and more international pressure in reducing greenhouse gas emis
Learn More -
2015-09-03 What is the annual leakage rate of sulfur hexafluo...
Air leakage rate has always been the focus of attention of manufacturers and users. The annual leakage rate of SF6 load switch and inflation cabinet is less than 1%/ year. The service life of the switch is generally about 30 years. Sealing should take into account the compression of sealing components, life, aging, reliability factors.
Learn More -
2015-08-20 SF6 concentration online monitoring system main co...
Host: receives the data uploaded by the monitoring unit, summarizes, analyzes and displays it, and controls the corresponding output (alarm, starting and stopping the fan) according to the data analysis results;
Learn More -
2015-07-26 What are the control conditions for fan linkage co...
1) Automatic start if the indoor state is abnormal: if the sub-regional control function is not defined, the system will automatically start the fan if the SF6 concentration or oxygen level alarm of any indoor detection unit is generated. The duration of continuous ventilation is the set time for continued ventilation until SF6 and oxygen are restored to normal.
Learn More