Q&A
-
2016-10-18 What are the functional features of the SF6 microm...
The SF6 microwater meter (Winfoss-P6) uses Finnish Vysala polymeric film resistance-capacitance sensors to measure accurately and reliably over the full range, and has excellent long-term stability. It is not affected by dust particles and most chemical pollution, making it ideal for use in industrial environments.
Learn More -
2016-10-18 What are the advantages of the SF6 Gas Recovery Un...
The SF6 Gas Recovery Purification Purification aeration System (Winfoss-R2) is used to separate air and CF4, low fluoride decomposition from SF6. The separation system is based on the principle of direct liquefaction without oil at high pressure to carry out preliminary liquefaction filtration of recycled SF6 gas, and then rely on the low temperature cooling system to further liquefy and solidify the mixture of gas and liquid in the separator. Nitrogen is slowly separated and discharged, while S
Learn More -
2016-10-03 What is the meaning of the critical temperature an...
From the basic physical characteristics of SF6 gas, it can be seen that it is relatively easy to liquefy gas compared with air. The state of SF6 gas depends on parameters such as its pressure and temperature.
Learn More -
2016-09-30 How to produce SF6 decomposition products in high ...
SF6 electrical equipment internal insulation materials, including SF6 gas and solid insulation materials two categories. SF6 gas is common to all SF6 electrical equipment, while solid insulation materials vary from equipment to equipment, mainly thermosetting epoxy resin, polyester nylon, polyester vinyl, polytetrafluoroethylene, insulating paper and insulating paint. The decomposition temperature and decomposition products of different insulating materials are different. Among them, at 130℃,
Learn More -
2016-09-30 What are the main factors in the decomposition of ...
Pure SF6 gas is colorless, tasteless, non-toxic, non-flammable inert gas, its own decomposition temperature is greater than 500 ° C, in the normal operation of the decomposition products are very few, but when co-existing with metal materials, at 200 ° C it is possible to occur trace decomposition. As the insulating medium of gas-insulated combined electrical apparatus (GIS), sulfur hexafluoride (SF6) gas has excellent insulation and arc extinguishing performance, and can greatly reduce the size
Learn More -
2016-09-26 With an SF6 dew point meter, why install a micro w...
The measurement of SF6 dew point meter has the following defects: A. Not online SF6 dew point meter is used for regular detection, which is a non-online detection method, and can not reflect the operating status and dynamic changes of the equipment in real time. The maintenance of equipment and the automation of power distribution network in the true sense cannot be realized.
Learn More