Q&A
-
2017-06-02 What should I pay attention to when SF6 equipment ...
1, the SF6 gas to be recycled needs to be purified and can be used only after reaching the new gas standard. The exhaust gas must be purified in advance (such as the method of alkali absorption) to meet the national environmental protection standards before it can be discharged.
Learn More -
2017-05-27 What is the main function of SF6 gas density micro...
SF6 gas density micro-water online monitoring device is mainly used for online monitoring of the circuit breaker SF6 gas micro-water, temperature and its change trend. When SF6 gas indicators change, the change curve is given, and when the indicators exceed the standard and reach dangerous conditions, the alarm device is automatically started, and the monitoring data is uploaded to the upper monitoring host and the management center station in real time to ensure the safe operation of the equipm
Learn More -
2017-05-21 What is the role of the SF6 Gas Density micro-wate...
At present, the pressure of most high-pressure GIS equipment in operation is still mainly using traditional mechanical density relays. When SF6 electrical products leak, they can send alarm and lock contact signals, which is a passive protection and cannot reflect the hidden dangers of equipment and prevent them in advance. For example, gas leakage will directly pollute the environment, such as equipment in a relatively sealed environment. It may also cause personal injury. However, the micro-wa
Learn More -
2017-05-19 What are the hazards and prevention of sulfur hexa...
Sulfur hexafluoride (SF6) gas is one of the six greenhouse gases found today. A large amount of SF6 gas is used in the high-voltage electrical appliance manufacturing industry. Due to improper use, management or failure to recover and regenerate it in a correct way, SF6 gas and the toxic decomposition produced under the action of high-temperature arc are discharged into the atmosphere, which brings pollution and destruction to the environment on which human beings depend. At the same time, it wi
Learn More -
2017-05-19 What are the functional characteristics of XP-1A S...
XP-1A SF6 gas qualitative leak detector unique sensitivity adjustment, original tracking of the leak point, power display, simple operation, easy to carry, fully intelligent, anti-pollution, anti-interference, good repeatability, fast response, high sensitivity, high stability, microprocessor control, with advanced digital signal processing, three-color visual display, including noise suppression characteristics, Seven sensitivity levels, offering up to 64 times the order of magnitude, cordless
Learn More -
2017-05-19 What is the difference between SF6 qualitative lea...
1) SF6 qualitative leak detector is mainly used to roughly detect SF6 gas leakage. 2) SF6 gas quantitative leak detector is suitable for the power supply department, installation and maintenance units and electric power test research institute, but also suitable for SF6 high-voltage switch factory as SF6 electrical equipment and export products supporting instruments testing.
Learn More