News Center
-
2016-12-28 How to deal with SF6 gas leakage in high voltage e...
When a large number of SF6 gas leaks occur in high-voltage electrical equipment, emergency protective measures should be taken to evacuate the gas leak site, and the relevant leaders of the company should be reported immediately. When poisoning occurs, personnel should be immediately evacuated from the scene and transferred to a well-ventilated place for rest.
Learn More -
2016-12-20 Can the SF6 leakage monitoring and alarm system de...
Substation outage maintenance is not directly related to Weavers' SF6 leakage monitoring alarm, as long as the system remains powered on, when excessive leakage occurs, it must generate an alarm and control the operation of the automatic fan. Unless the host and fan power supply is also in a state of power failure. In order to avoid the occurrence of this situation, the monitoring host power input should be connected to the uninterrupted power circuit during installation.
Learn More -
2016-12-18 What are SF6 online monitoring systems?
SF6 online monitoring system includes SF6 leakage monitoring system, SF6 density pressure online monitoring system, SF6 density micro-water online monitoring system, SF6 decomposition online monitoring system.
Learn More -
2016-12-16 What are the advantages of SF6 density micro-water...
• Meets the needs of intelligent substation construction, realizes the digital monitoring and remote monitoring of density micro-water, and status maintenance; • Real-time reflection of equipment operating status and dynamic changes; • Remote monitoring, unmanned station; • Reduce emissions of the gas; • Good for the health of on-site staff; • Reduce unnecessary costs and losses; • Improve work efficiency and safety.
Learn More -
2016-12-15 In SF6 electrical equipment, what is the effect of...
The source of surface contamination is likely to be impurities during equipment assembly and metal particles generated during switch operation, which will reduce flashover voltage and increase dispersion. In addition, arc discharge and corona discharge during operation will cause SF6 gas decomposition to produce low fluoride SF4, SOF2, SO2F2, etc. Under the action of water and oxygen, corrosive HF and SO2 will be generated, making the insulation material corroded and deteriorated, and the insula
Learn More -
2016-12-14 What are the methods for SF6 gas treatment on site...
SF6 electrical equipment under normal operation, SF6 impurities can generally be treated on site to remove. The treated SF6 gas must meet the reuse standard, and the SF6 gas is recharged to the electrical equipment for reuse.
Learn More